SCR Power Controller Products
Product Search
Advanced SearchOther Applications
Saturable Core Reactors (VRTs), Control of field current for motors/generators, brakes & clutches, control of ultra-violet lamps
| Model | Phase | Mode | Voltage | Current | Highlights |
|---|---|---|---|---|---|
| 1022 | One | Phase Angle | 120-575 Vac | 10-70 Amps @ 55°C | Accepts Vdc and potentiometer commands. |
| 1025 | One | Phase Angle | 120-575 Vac | 10-70 Amps @ 55°C | Accepts mA commands. |
| 1029C | One | Phase Angle | 120-575 Vac | 50-2000 Amps @ 55°C | Higher current ratings than our solid state relay models. Features include: current limiting, shorted SCR detection, over-current trip, metering outputs, user selectable feedback modes. |
| 1032A | One | Phase Angle | 120-575 Vac | 10-70 Amps @ 55°C | Accepts most commands. Field adjustable current limiting. |
| 1039 | One | Phase Angle | 120-575 Vac | 10-180 Amps @ 55°C | Accepts most commands. Features include: on-board line fusing and metering outputs. Optional card adds: current limiting, shorted SCR detection, over-current trip and a second command setpoint. |
| 1802 | One | DC | 120-575 Vac | 10-40 Amps halfwave rectified DC @ 55°C | Accepts Vdc or potentiometer commands. 60Hz halfwave DC output. |
| 1805 | One | DC | 120-575 Vac | 10-40 Amps halfwave rectified DC @ 55°C | Accepts mA commands. 60Hz halfwave DC output. |
| 1822 | One | DC | 120-240 Vac | 10-30 Amps fullwave rectified DC @ 55°C | Accepts Vdc or potentiometer commands. 120Hz fullwave DC output. |
| 1825 | One | DC | 120-240 Vac | 10-30 Amps fullwave rectified DC @ 55°C | Accepts mA commands. 120Hz fullwave DC output. |
| 2022 | One | Phase Angle | 120-575 Vac | 10-70 Amps @ 55°C | Accepts most commands. Dual setpoints for fast transistions. |
| 3629C | Three | Phase Angle | 208-575 Vac | 50-1000 Amps @ 55°C | Higher current ratings than our solid state relay models. Features include: current limiting, over-current trip, shorted SCR detection. |
| 3869 | Three | DC | 120-480 Vac | 300-400 Amps fullwave rectified DC @ 55°C | Accepts most commands. High current, three phase DC output. |